JLG winter maintenance tips for aerial lifts
JLG shares winter prep steps for aerial lifts. Focus on batteries, moisture in controls, proper oils, and optional heater packages to keep MEWPs working.
JLG winter maintenance guidance landed on Nov 20, 2026, aimed at keeping aerial lifts and MEWPs productive when temperatures drop. The advice focuses on batteries, moisture in controls, and cold-rated fluids, with options for heater kits for extreme cold, according to an interview on constructionequipment.com.
For contractors and rental fleets, the message is simple, act before the freeze. Verify your fluids match expected ambient temps, harden your electrical system against moisture, and make charging part of the daily plan. These steps reduce no-starts, frozen controls, and mid-shift downtime.
What JLG is telling fleets
JLG advises starting winter prep before the first real cold snap. Get machines current on recommended maintenance and repairs, then open the Operation and Safety Manual to confirm the correct engine oils, hydraulic oils, lubricants, and fuels for the temperatures you expect on site. Cold-thick fluids slow functions and stress pumps. The right grades keep lifts responsive and protect components.
Electrical systems deserve the same upfront attention. JLG calls out secure, tight, corrosion-free battery connections. Inspect exposed electrical components and cannon plugs for moisture. Where appropriate, apply dielectric grease to help seal out water and fight corrosion. On diesel-powered units with glow plugs, verify the system is set correctly per the manufacturer’s instructions so cold starts are predictable.
Daily winter inspection checklist
Add winter-specific checks to the usual walk-around so issues get caught before the platform goes up. JLG’s guidance centers on batteries, moisture control, and the health of switches and joysticks.
- Confirm battery posts and cables are tight and corrosion-free
- Inspect cannon plugs for moisture and apply dielectric grease where appropriate
- Check toggle switch and joystick boots at platform and ground controls for damage
- Verify diesel glow plug setup follows the manufacturer’s instructions
- Stay current on all manual-required inspections and preventive maintenance
These checks belong in the pre-shift routine. Water in a switch or a cracked boot can freeze and take a lift out of service. A loose battery cable can show up as slow functions or a no-start when temperatures fall.
Battery care in the cold
Cold weather hits batteries hard, so JLG puts extra weight on battery condition and charging habits. Before and throughout the season, make sure batteries and their connections are secure and free of corrosion. For lead-acid batteries, check water levels and top off with distilled or deionized water, not tap water. Address aged or weakened batteries before they strand an operator at height.
For battery-powered MEWPs, state of charge matters more in winter. Keep batteries fully charged. When possible, charge overnight and charge indoors or in a warmer area so packs start the day warm and topped up. That practice helps lift speed and reduces voltage sag under load in cold air.
Follow the battery and equipment manufacturer’s inspection and maintenance procedures. If your team rotates chargers or swaps machines between jobs, make the charging plan part of dispatch so no unit arrives on site undercharged.
Moisture and frozen controls
Moisture is a recurring theme in JLG’s winter advice. Inspect cannon plugs for signs of water and protect exposed electrical components as appropriate. Joysticks and toggle switches need special attention, at both platform and ground controls. Damaged protective boots let water in. That water can freeze, and a frozen or shorted control can make the machine inoperative.
In practice, that means touching every boot during the walk-around, looking for cracks, tears, or gaps, and replacing failed covers quickly. If a lift sat through a thaw-freeze cycle or a freezing rain event, plan a few extra minutes to cycle controls slowly after warmup and confirm full range of motion before sending anyone up.
Fluids and cold-start readiness
Choosing the right fluids is not optional in winter. JLG points operators back to the Operation and Safety Manual to confirm the correct engine oil, hydraulic oil, lubricants, and fuels for the expected temperature band. The wrong viscosity can delay lift, swing, or drive response and can trip fault codes that disappear after warmup, wasting troubleshooting time.
Diesel machines also need proper glow plug setup. Verify settings and operation against the manufacturer’s instructions before the cold arrives. That quick confirmation saves batteries from repeated crank attempts and reduces starter wear when the jobsite turns icy.
Cold weather options and storage practices
For fleets that work in extreme cold, JLG notes optional cold-weather packages. These can include heaters for the battery, the hydraulic tank, and the engine breather. If your projects run through long cold snaps or you park machines outside, talk with your dealer or rental provider about availability and installation timing so kits are in place before the next front moves in.
Storage and charging location matter. When possible, park and charge indoors or in a warmer spot overnight. Starting the day warm helps batteries deliver current and reduces the likelihood of frozen controls and sluggish hydraulics.
What contractors and rental fleets should do now
Based on JLG’s guidance on Nov 20, 2026, treat winterization as a scheduled task, not an emergency fix. Update fluids to the manual’s winter grades. Inspect every electrical connection you can reach, apply dielectric grease where appropriate, and replace torn joystick and toggle boots. For diesel units, confirm glow plug setup per the book.
Make charging a plan, not a hope. Keep batteries fully charged, charge overnight, and, when you can, do it indoors or in a warmer bay. For lead-acid packs, check water levels and use distilled or deionized water. If a battery shows age or weakness, address it before it costs you a morning.
If you operate in harsher conditions, ask about JLG cold-weather packages that add heaters for the battery, hydraulic tank, and engine breather. Those add-ons help machines start and function when the air hurts your face. Align that investment with utilization, the machines that live outdoors, and the jobs you cannot slip due to weather.
Decision takeaway, start these checks before the freeze, get fluids and electricals right, and lock in consistent charging. That plan cuts winter breakdowns and keeps your lifts earning instead of idling in the yard. JLG winter maintenance is simple work, and it pays off when the mercury drops.